• HOME
  • PRODUCTS
    • ANESTHESI MACHINE>
      • ADOX AS 3000
    • BLOOD BANK>
      • CN- 350 BB
      • CM 700 BB
      • CM 900 BB
      • CM 1100 BB
    • BLUE LIGHT>
      • CFL 101
    • COLPOSCOPE>
      • PE-7000-BRDC-5
    • DEFIBRILLATOR>
      • RESCUE 230
    • ECG>
      • CARDIOGIMA 1M
      • CARDIOGIMA 3M
      • CARDIOGIMA 6M
    • ELECTROSURGICAL UNIT>
      • SURTRON 120
      • SURTRON 200
      • SURTRON 300 HP
      • SURTRON 400 HP
    • FETAL DOPPLER>
      • DF 4000 D
    • FETAL MONITOR (CTG)
    • GYNECOLOGICAL TABLE>
      • GOLEM F1
      • LEMI - GYNO
    • INCUBATOR>
      • INCUBATOR BABY
      • INCUBATOR TRANSPORT
    • INFUSION PUMPS‎ >
      • BSV 700
      • NB-400
    • INFANT WARMER>
      • NOC 100
    • NEBULIZER>
      • COMPRESSOR
      • ULTRASONIC
    • OPERATING LAMP>
      • HALOGEN
      • LED
    • OPERATING TABLE>
      • MC-257
      • MC 357
    • PATIENT MONITOR>
      • DS-5000A
    • PULSE OXIMETER
    • PHYSIOTHERAPY>
      • ELECTRO THERAPY
      • LASER THERAPY
      • MAGNETOTHERAPY
      • MICROWAVE THERAPY
      • ULTRASOUND THERAPY
    • ‎SYRINGE PUMPS>
      • BSS 100
    • SUCTION PUMPS>
      • ASPIRA MAX DC
      • ASPIRA MAX AC
      • VEGA 28210
      • HOSPI PLUS 28204
      • TOBI CLINIC 28231
    • STERILISATOR>
      • DT 80
  • INSTRUMENTS
  • ABOUT US
  • CONTACT US
  • LOCATION
  • EVENTS
  • OUR BRANDS
  • GALLERY
Electro Surgical Unit - Surtron 300HP
File Size: 496 kb
File Type: pdf
Download File

Picture

SURTRON 300  HP

_Can be used to execute monopolar and bipolar surgery in the many fields of application where it is requested high precision and reliability
SURTRON® HP can be used to execute monopolar and bipolar surgery in the many fields of application where it is requested high precision and reliability.

TWIN OPERATIVE ACTIVITY
  • Two output channels for monopolar cutting
  • Two independent setting and output channels for the most frequent monopolar coagulation
CONTROLLED CUTTING PROCEDURES
  • Enhanced cutting current for eschar free incision
  • Cutting current with selectable coagulating property for bleeding controlled dissection
  • Low capacitive coupling by slow BLEND current for endoscopic procedures
TWIN CONTROLLED COAGULATIVE PROCEDURES
  • SPEEDY* coagulation and DEEP**coagulation available to two operators
  • SPRAY coagulation available by hand switch or foot switch controls
WIDE BIPOLAR FEATURES
  • Bipolar cutting current with selectable bleeding control
  • Slow BLEND cutting current
  • Separately activable Automatic Start/Stop coagulation (Detection system of tissue impedance)
SURGEON AND PATIENT TOTAL SAFETY
  • Acceptability of contact impedance between patientbody and return electrode continuously watched by Skin Plate Electronic Control (SPEC)
  • H.F. Leakage currents continuously monitored
  • Mains fluctuation automatically compensated before to start the delivery of HF power

PERSONALIZED PROCEDURES
  • Independent choise of coagulative currents and power levels by each of two operators
  • Ten personal configurable and immediately recallable procedures
EXTENTION DRIVER AND INTERLOCK SIGNALS
  • Drived output connection to external Argon Plasma unit and Smoke Evacuator unit
AUTOMATIC SELF DIAGNOSIS
  • Automatic diagnostic control of the actual complete functionality of the electronic unit and the connected accessories with coded report of failures
  • SPEEDY coagulation also said Fulgurate or Forced coagulation
  • DEEP coagulation also said Pin Point, Dessicate or Soft coagulation
CONTROLS
  • Patient/Plate circuit monitoring
  • Output power monitoring
  • Self check control
  • H.F. Leakage currents control
  • Compensation of mains fluctuation
SAFETY
  • EN60601-1
  • EN60601-1-2
  • EN60601-2-2
  • Electrical Class: I CF
  • MDD 93/42/EC Class: II b
SURTRON®HP

Reference code
Maximum output power monopolar pure CUT
Maximum output power monopolar cut-coag CUT80%
Maximum output power monopolar cut-coag CUT60%
Maximum output power monopolar cut-coag CUT40%
Maximum output power monopolar cut ENHANCED
Maximum output power monopolar cut-coag BLEND
Maximum output power monopolar coag SPEEDY
Maximum output power monopolar coag DEEP
Maximum output power monopolar coag SPRAY
Maximum output power monopolar coag SPRAY ARGON
Maximum output power bipolar CUT
Maximum output power bipolar cut-coag CUT80%
Maximum output power bipolar cut-coag CUT60%
Maximum output power bipolar cut-coag CUT40%
Maximum output power bipolar cut-coag BLEND
Maximum output power bipolar coag COAG
Working frequency Monopolar / Bipolar
Patient circuit
Selectable input voltage
Mains frequency
Electrical input power
Weight Kgs
Size WxHxD mm
300 HP

10400.801
300 W→ 300 Ω
250 W → 300 Ω
200 W → 300 Ω
150 W → 300 Ω
200 W → 500 Ω
200 W → 300 Ω
100 W → 500 Ω
100 W → 200 Ω
70 W → 2000 Ω
70 W → 2000 Ω
95  W → 150 Ω
95  W → 150 Ω
95  W → 150 Ω
60 W → 150 Ω
90 W → 150 Ω
70 W → 100 Ω
425 kHz / 525 kHz
F
115- 230 Vac
50 - 60 Hz
1000 VA
17.5
470x150x400