Rescue 230.pdf | |
File Size: | 1152 kb |
File Type: |
_GENERAL FEATURE
- BTE (biphasic truncated exponential) discharge type - Impedance compensated energy delivery - Energy selection from 10 to 230 Joule directly from the front panel. - Charge time 5 sec for 230 Joule with fully charged battery - 100 shocks of 230 J with fully charged batteries - Charge/discharge control from the paddles - Ecg 'R' wave synchro mode or async mode - Can be used with disposable paddles - Large (5.7") high resolution backlite LCD display (320x240 dots) - ECG through the paddles or through patient cable |
Technical Specifications
• Display:
- Large (5.7"") high resolution backlit LCD display (320x240 dots)
- ECG through the discharge paddles (1 trace) or through 4 leads patient cable (6 traces): I, II, III, aVR, aVL, aVF.
Automatic change over when plugging the patient cable
- Filters: 50 Hz/60 Hz, base line, low pass
- Heart rate indicator
• Printer:
- Integrated thermal printer for ECG traces and events documentation hardcopy
- Paper speed 5, 10, 25 and 50 mm/sec. (paper width 58 mm)
• Safety:
- Two hand safety shock release
- Ecg input isulation CF class
- Internal discharge after 30 sec. of standby after charge
• Power supply:
- internal Ni-Cd high capacity batteries (charging time 95%: 2 hours)
- universal mains adaptor charger 110/220 VAC, 50/60 Hz
• Dimensions: 34 x 26 x 13 cm
• Weight: 5.5 kg
• Made in Italy
Standard accessories
• Internal Ni-Cd high capacity battery
• Carrying case
• Patient cable 4 leads
• Disposable paddle + cable
• Printer
• 1 paper roll
• 2 reusable paddles
• Mains adaptor charger
• User manual (english, italian) spanish and turkish on request
• Display:
- Large (5.7"") high resolution backlit LCD display (320x240 dots)
- ECG through the discharge paddles (1 trace) or through 4 leads patient cable (6 traces): I, II, III, aVR, aVL, aVF.
Automatic change over when plugging the patient cable
- Filters: 50 Hz/60 Hz, base line, low pass
- Heart rate indicator
• Printer:
- Integrated thermal printer for ECG traces and events documentation hardcopy
- Paper speed 5, 10, 25 and 50 mm/sec. (paper width 58 mm)
• Safety:
- Two hand safety shock release
- Ecg input isulation CF class
- Internal discharge after 30 sec. of standby after charge
• Power supply:
- internal Ni-Cd high capacity batteries (charging time 95%: 2 hours)
- universal mains adaptor charger 110/220 VAC, 50/60 Hz
• Dimensions: 34 x 26 x 13 cm
• Weight: 5.5 kg
• Made in Italy
Standard accessories
• Internal Ni-Cd high capacity battery
• Carrying case
• Patient cable 4 leads
• Disposable paddle + cable
• Printer
• 1 paper roll
• 2 reusable paddles
• Mains adaptor charger